Standard safety switches
Please contact us for data sheets on the individual safety switches.
Safety switch 1563
without arrest
Description
NC contact with forced opening, 1 NC contact, 1 NO contact, without arrest, min. IP65 / IEC 60529
Function
Standard switch till Vn <= 1,00 m/s
Safety switch as a pre-cut-off safety switch 2230
with arrest
Description
NC contact with forced opening, 1 NC contact, with arrest, min. IP65 / IEC 60529
Function
Pre-cutt-off safety switch off from Vn = 1.00 m/s, switches max. 10 % before release speed
mechanical and electrical resetting
Attention: The safety switches for a pre-switching can only be retrofitted by the manufacture.
No additional safety switch is required, which means less installation effort.
Safety switch 1562
without arrest
Description
NC contact with forced opening, 2 NC contacts, without arrest, min. IP65 / IEC 60529
Function
Same as 1563, but with an opener for the safety circuit and an opener for triggering an additional brake
Safety switch 1564
with arrest
Description
NC contact with forced opening, 1 NC contact, 1 NO contact, with arrest, min. IP65 / IEC 60529
Function
Same as 1563, with arrest
Safety switch as a pre-cut-off safety switch 2240
with arrest
Description
NC contact with forced opening, 2 NC contacts, 1 NO contact, with arrest, min. IP65 / IEC 60529
Function
Same as pre-cut-off 2230, with electromagnetic reset an 2 NCC and 1 NOC
Ue/Ie = 230VAC/4A
Ue/Ie = 24VDC/4A
Attention: The safety switches for a pre-switching can only be retrofitted at the factory.
No additional safety switch is required, which means less installation effort.
One NC contact each for disconnecting the safety circuit and activating an additional brake.
Safety switch 1570
Without arrest
Description
NC contact with forced opening, 2 NC contacts, 1 NO contact, without arrest, min. IP65 / IEC 60529
Function
To activate an additional brake
Safety switch 1475
With arrest
Description
NC contact with forced opening, 2 NC contacts, 1 NO contact, with arrest, min. IP65 / IEC 60529
Function
Vn <= 1.0 m/s to Va = 1.50 m/s with electromechanical resetting
Safety switch 2500
With arrest
Description
NC contact with forced opening, 2 NC contacts, with arrest, snap action, min. IP65 / IEC 60529
Function
Safety switch with 2 NC
Safety switch for direction-dependent switching 1563
Without arrest
Description
NC contact with forced opening, 1 NC contact, 1 NO contact, without arrest, min. IP65 / IEC 60529
Function
Dependent on direction to activate an additional brake
Safety switch for direction-dependent switching 1564
With arrest
Description
NC contact with forced opening, 1 NC contact, 1 NO contact, with arrest, min. IP65 / IEC 60529
Function
Dependent on direction to activate an additional brake
Directional switching is possible with the two safety switches of type 1563 and 1564 as additional safety switches.